Unique techniques |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
In situ Analyzers Technologies in combination with modular Sensor Systems for size and morphologies of Population
Unique proved techniques for MTS in production particle SYSTEM in situ size measurement particle size analyzer for in line Integrated Industry Solutions like 4.0
MTS 3D ORM Autofocus FBRM patent Signal-lens technique
Version March 2016
MTS 3D ORM FBRM Signal lens technique is a patented technology developed by MTS.
MTS 3D ORM Autofocus in combination FBRM Signal lens technique integrates forward, lateral and backward optical signals. Our focal based <2°light paths angle reduce unwanted scattering light effects, so that detection quantity of back reflected lights will be doubled. Compare with single lens multi mode laser particle system size analyzer, this technique improves measuring range dramatically, measuring accuracy for fine particles and resolution ratio. Compare with MTS 3D ORM Autofocus FBRM Signal-beam laser particle size analyzer, the technique improves reliability and reduces failure rate under process condition. The high tech Sapphire window surface prevents any fouling and contamination under process condition. To realize safety aspects of in process measurement and control via Bus and PLT
Benefits:
MTS Automatic alignment focus technique
Benefits:
Unique MTS calibration technique for accuracy
All instruments are passed through the calibration by MTS reticular System. In addition different standard calibration sample, will guarantee the accuracy of the instrument's test results. Standard sample is provided along with the instruments at the same time. Users can check up the accuracy of the instrument at any time by MTS reticular System, which may avoid losses caused by inaccurate test results due to instrument relocation, voltage/photon/laser/damping fluctuation and other factors which can be found by internet link in connection with the MTS service team.
Benefits:
o 2013 all units operate on 98,50% o 2014 all units operate on 98,85% o 2015 all units operate on 98,75%
Reliable circulation & dispersion system is in general not needed - but available
The MTS Sensor is normally directly installed inside a reactor or up streaming piping system. Wet dispersion systems are normally not needed. Ultrasonic disperser can be directly engaged with the MTS 3D ORM Sensor System. Based on the LIE which can be optional adapted between 1 and 30 mW MTS normally can operate in customer application fields.
Benefits:
Dirt and contamination protection technique of sensor window and lenses
All models of MTS in production particle system in situ size measurement of particle analyzer are equipped with electrochemical polished sapphire windows based on the highest military optical standard contamination protection. The inside sensor the lens systems and the optomechanical system can be protected optional by inert gas flushing for condensate and dirt
Benefits:
Automatic water suction technique and cost of treatment is not needed.
MTS in production particle system insitu sensor size measurement particle analyzers are directly in operation inside the media which should be analyzed! Therefore MTS Sensor Systems does not necessarily need equipped with the water suction pump and water level measuring device, which can automatically pump the water in the bucket into the circulation tank for later treatment.
Benefits:
Multi - language handling and operation
Customer languages are provided in the MTS’s
software of laser particle analyzer including Simplified Chinese,
Traditional Chinese*, English, Russian, German, Korean, etc. Users just
select one of the languages; the software interface will turn into the
corresponding language.
*under final test beta test planed to be launched in 2016
Benefits:
Measuring technique for operation under dew point temperature
For the MTS laser particle
analyzer running in high humidity environment, the technique will play a
big role in ensuring instruments run in the normal condition and
accurate test results can be obtained. Because in high humidity
environment, mistreat is easy to condense on the inside surfaces optics
of the Sensor. The sensor must be purged under this condition with a
clean nitrogen gas. If condensation accurse the
MTS would go in a alarm status.
Benefits:
High-speed sampling signal technology
By adopting the Multi Capture Signal Technology (MCST) and
high-speed AD technique, sampling rate of MTS’s
laser particle analyzer can reach in the most sophisticated versions
250.000 captured signals per second.
So the system can accurately capture the back reflected signals of
particles when they passing the Autofocus driven by the single mode 4
micron the laser beam, which avoids the distortion caused by out of
focus area. MCST ensure the accuracy and repeatability of the result.
High-speed signal sampling technique is particularly important in the
dry powder application where the flow speed is high.
Benefits:
Report conversion technique
Just by clicking a button, you can easily convert report into format of
BMP, JPG, PDF or Excel as you need.
All measured parameters can send to Process Control Computer by digital
or analogue signals
Benefits:
Results
of laboratory reticular test by MTS
Test result for MTS 3D ORM SMF In
Process Particle MTS size analysis of 50 + 100 + 250 + 400 +600 + 1000
micron insitu reticular test module
MTS
Instrument participated in the "Proficiency testing plan of Particle
size analysis in 2015. Lab code is 15/03/15 mts.
Reticule
Result µm
expected
Deviation %
Results
050
48,46
50
3,06
excellent
100
98,13
100
2,87
excellent
250
246,67
250
1,33
excellent
400
394,23
400
1,44
excellent
600
589,50
600
1,75
excellent
1000
982,15
1000
1,79
excellent
Copy
rights by MTS 2020 |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|